This standard specifies the most basic safety requirements for design, manufacture, installation, inspection, use and management, etc. of passenger aerial ropeway.
It is applicable to reversible passenger aerial ropeway and circulating passenger aerial ropeway.
It is not applicable to material ropeway, passenger funiculars, hauling ropeway, non-public passenger ropeway and commuting ropeway for mine and down-hole use.
2 Normative References
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB 146.2 Structure Gauge for Standard Gauge Railway
GB/T 188 Locomotive and Car Clearance Boundary and Structure Clearance Boundary for 762mm Gauge Railways: Classification and Basic Dimensions
GB/T 229 Metallic Materials - Charpy Pendulum Impact Test Method
GB/T 352 Locked Coil Wire Ropes
GB/T 1031 Geometrical Product Specifications (GPS) - Surface Texture: Profile method - Surface roughness Parameters and Their Values
GB/T 8918 Steel Wire Ropes for Important Purposes
GB/T 9075 Code for Examination and Discard of Ropes for Ropeway
GB/T 24731 General Technical Conditions for Drive of Passenger Ropeway
GB/T 24732 General Technical Conditions for Support (Compression) Sheave of Passenger Ropeway
GB/T 26722 Steel Wire Ropes for Ropeway
GB 50007 Code for Design of Building Foundation
GB 50009-2012 Load Code for the Design of Building Structures
GB 50010 Code for Design of Concrete Structures
GB 50017 Code for Design of Steel Structures
GB 50061 Code for Design of 66kV or under Overhead Electrical Power Transmission Line
GB 50231 General Code for Construction and Acceptance of Mechanical Equipment Installation Engineering
NB/T 47013
(all parts) Nondestructive Testing of Pressure Equipment
DL/T 1561.1~1561.17 Specification for Construction Quality Checkout and Evaluation of Electric Equipment Installation C Part 1: General Rules
3 General Requirements
3.1 Line
3.1.1 Line selection
3.1.1.1 In case of ropeway line selection, such things shall be taken into consideration as requirements of local climate, geographical conditions, main traffic lines that the ropeways cross over and other building facilities that they cross over as well as the emergency rescue.
3.1.1.2 The projection of the center line of ropeway line on a plane shall be a straight line (ropeway with angle station and triangle ropeway are exceptional).
3.1.1.3 The following areas shall be avoided for construction of ropeway line and station site:
——the areas at air outlet of hilly area, which is orthogonal to the prevailing wind direction;
——the areas with factors such as avalanche, landslide, collapse, karst cave, windstorm, tsunami, flood and fire, etc. that endanger safety of the ropeway, unless approved by the competent departments and provided with preventive measures;
——corresponding measures shall be adopted for any ropeway constructed near military installation according to the requirements of military base management organizations.
3.1.2 Maximum inclination angle
Maximum inclination angle of steel wire rope of circulating passenger aerial ropeway shall not be greater than 0.785 rad.