This standard specifies the product classification, specification/dimension, technical requirements, test methods, inspection rules as well as marking, packaging, transportation and storage of wood fire door.
This standard is applicable to the fire doors using wood or wood products as door frames, door leaf skeletons and door leaf panels.
2 Normative references
GB 191 Packaging - Pictorial marking for handling of goods
GB 5464 Non-combustibility test method for building materials
GB 5823 Terminology for building windows and doors
GB 5824 Size system of opening for windows and doors in building
GB 5825 Symbolic designation of direction of opening and closing and faces of doors and windows
GB 6388 Transport package shipping mark
GB 7633 Fire resistance tests - Door and shutter assemblies
GB 13685 Graduation of resisting wind pressure capacity and the test method for building external doors
GB 13686 Graduation and test methods of air permeability and water penetration for building external doors
GBJ 16 Code for fire protection design of buildings
GBJ 45 Specifications for the design of highrise civil buildings (trial) - Fire prevention
GBJ 206 Specifications for construction and acceptance of timber structure
GBJ 210 Specification for construction and acceptance of decoration projects
TJ 9 Load code for industrial and civil building structures
3 Terms, symbols and codes
3.1 Wood fire door refers to the door with wood or wood products as door frame, door leaf skeleton, door leaf panel and fire resistance rating meeting the requirements of 4.4.1, GBJ 45.
3.2 The name symbol of wood fire door shall be MFM according to GB 5823.