This standard specifies the requirements for compatibility and connectability of automatic fire alarm system components.
This standard is applicable to the compatibility and connectability assessment of automatic fire alarm system components.
2 Normative References
The provisions of the following standards, through reference into this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties whose enter into agreement according to this standard are encouraged to research whether the latest editions of these documents are applied or not. For undated references, the latest edition of the normative document is applicable to this standard.
GB 4717 "Fire Alarm Control Units"
GB 14287.1 "Alarm System for Electric Fire Prevention-Part 1: Alarm Control Units for Electric Fire Prevention"
GB 16806 "Automatic Control System for Fire Protection"
GB 16808 "Combustible Gas Alarm Control Units"
3 Terms and Definitions
The following terms and definitions apply in this standard.
3.1
Component type 1
The device required having the function of protecting the life and property safety in accordance with the national standards or codes.
3.2
Component type 2
The device not required having the function of protecting the life and property safety in accordance with the national standards or codes.
3.3
Compatibility
The ability for the components type 1 to work by connection.
3.4
Connectability
The ability for the component type 2 and component type 1 to work by connection.
4 General Requirements
4.1 General
The compatibility and connectability of the automatic fire alarm system (the system functions are detailed in Appendix A) components shall firstly meet the requirements of this chapter, and then shall be tested according to the requirements of Chapter 5 and shall meet the test requirements. Moreover, the automatic fire alarm system components shall be carried out with the compatibility and connectability assessment according to the requirements of Chapter 6 and shall meet the test requirements of assessment.
4.2 Compatibility requirement
4.2.1 The component classification of the automatic fire alarm system and connecting device (or parts) shall comply with those specified in Appendix B, components type 1 shall adopt the product certificated by the fire product quality supervision and inspection organization of the State. The operation of components type 2 shall not affect the normal operations of automatic fire alarm system.
4.2.2 The connected automatic fire alarm system components, such as independent (zone) fire alarm control units, combustible gas alarm control units, alarm control units for electric fire prevention and fire detectors, manual fire trigger device, combustible gas detectors, detectors for electric fire prevention and fire alarm devices, shall meet the following requirements respectively:
We use strictly necessary cookies to make our site work. We would also like to set optional analytics cookies
to help us improve it, and targeting cookies. We won't set optional cookies unless you enable them.
For more detailed information about the cookies we use, see our
Cookies Notice.
By clicking "Accept all cookies", you agree to the storing of cookies on your device for the purposes set out
in our Cookies Notice. Click "Reject non-essential" to refuse optional cookies.
Strictly necessary cookies are always active and cannot be disabled.
Cookie Consent Manager
Your Privacy
Websites may store or retrieve information on your browser, mostly in the form of cookies.
This information might be about you, your preferences, or your device and is mostly used to make
the site work as you expect it to. The information does not usually directly identify you, but it
can give you a more personalized web experience. Because we respect your right to privacy, you can
choose not to allow some types of cookies. Click on the different category headings to find out more
and change our default settings. However, blocking some types of cookies may impact your experience
of the site and the services we are able to offer.
These cookies are required for the operation of our website and use of its features, and therefore
cannot be switched off in our systems. They are usually only set in response to actions made by you
which amount to a request for services, such as setting your privacy preferences, logging in, or
filling in forms.
Functional Cookies
These cookies are optional and are used to remember the choices you have made.
These cookies are optional and are used to collect information on how visitors use our website.
Targeting Cookies
These cookies may be set to deliver advertising that is more relevant to you and your interests,
or to measure advertising effectiveness. California residents may opt out of the sale or sharing
of personal information via Do Not Sell/Share.
If this site does not currently run advertising pixels, enabling this category has no effect until such tools are added.