This Standard specifies grading and requirements, requirements for the show, safety management & assessment of fireworks show.
This Standard is applicable to fireworks operation.
2 Normative References
The following standards contain provisions which, through reference in this Standard, constitute provisions of this Standard. For dated reference, subsequent amendments to or revisions of, any of these publications (excluding correction content) do not apply. However, the parties coming to an agreement according to this Standard are encouraged to research whether the latest editions of these documents apply. For undated references, the latest edition of the document referred to applies.
GB 10631 Safety and Quality for Fireworks
GB 19593 Fireworks-Batteries and Combinations
GB 19594 Fireworks and Firecracker - Aerial Shell
GB 19595 Fireworks and Firecracker - Fuse
GB 20208 Fireworks and Firecracker - Barrel for Shells
3 Terminologies and Definitions
For the purpose of this Standard, the following terminologies and definitions apply.
3.1
Fireworks show
Operation that professional personnel set off certain quantity of fireworks and firecrackers such as aerial shells, combination fireworks, rack fireworks and stage fireworks via layout and design in an organized way on specified site and schedule time.
3.2
Operation
Such operations as equipment installation, product filling, circuit connection, ignition system testing and ignition control related to the show.
3.3
Firing equipment
Equipment controlling fire with current.
3.4
Electrical match
Firing materials composed of leg wire, bridge wire, drop-shaped igniting powder, protective paint and short circuit cover.
3.5
Explosion radius
The radius of maximum covering surface of single fireworks after explosion.
3.6
Safety distance
The shortest horizontal distance from show site to audiences, buildings and important places, etc.
3.7
Inside distance
The minimum distance between products or product groups.