GB 28235-2020 Hygienic requirements for ultraviolet appliance of disinfection
Hygienic requirements for ultraviolet appliance of disinfection
1 Scope
This standard specifies the raw material requirements, technical requirements, application scope, application methods, inspection methods, marking and packaging, transport and storage, nameplate and operating instructions of ultraviolet appliance of disinfection.
This standard is applicable to ultraviolet appliance of disinfection with C frequency-range ultraviolet (with the wavelength range of 200nm~280nm) as the sterilizing agent.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 191 Packaging - Pictorial marking for handling of goods
GB 5749 Standards for drinking water quality
GB/T 5750.2 Standard examination methods for drinking water - Collection and preservation of water samples
GB/T 5750.12 Standard examination methods for drinking water - Microbiological parameters
GB/T 10682 Double-capped fluorescent lamps - Performance specifications
GB/T 14294-2008 Central-station air handling units
GB/T 15144 A.C. supplied electronic ballasts for tubular fluorescent lamps - Performance requirements
GB 15982 Hygienic standard for disinfection in hospitals
GB/T 17219 Standard for safety evaluation of equipment and protective materials in drinking water system
GB/T 17262 Single-capped fluorescent lamps - Performance specification
GB 17625.1 Electromagnetic compatibility - Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
GB/T 17743 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
GB 17988 Safety and sanitation requirements for disinfecting tableware cabinet
GB/T 18202 Hygienic standard for ozone in indoor air
GB/T 18204.9 Methods of microbiological examination for water in swimming pool - Determination of aerobic bacterial count
GB/T 18204.10 Methods of microbiological examination for water in swimming pool - Determination of Coliform bacteria
GB 18466 Discharge standard of water pollutants for medical organization
GB/T 19258 Ultraviolet germicidal lamp
GB 19510.1 Lamp controlgear - Part 1: General and safety requirements
GB/T 19837 Ultraviolet (UV) disinfection equipment for urban water and wastewater engineering
GB 37488 Hygienic indicators and limits for public places
GBZ/T 189.8 Measurement of physical agents in workplace - Part 8: Noise
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
ultraviolet lamp
special electric light source directly using ultraviolet ray for disinfection
3.2
ultraviolet disinfection
disinfection method which is used to kill pathogenic microorganisms by making use of the principle that the genetic material of the pathogenic microorganisms that absorb the ultraviolet energy with a wavelength between 200nm~280nm will mutate and cause the cells to stop dividing and reproducing
3.3
ultraviolet appliance of disinfection
device that uses an ultraviolet lamp as the light source and ultraviolet ray emitted by the lamp as the sterilizing agent to disinfect pathogenic microorganisms on the transmission medium
3.4
ultraviolet appliance for air disinfection
ultraviolet appliance of disinfection that uses the combination of ultraviolet lamps, filter screen, fans and ballasts for air disinfection
Note: The filter screen and fan do not have the function of sterilizing agent.