1.1 This standard covers the evaluation of the oxidation stability of inhibited steam turbine oils in the presence of oxygen, water, and copper and iron metals at an elevated temperature. This test method is limited to a maximum testing time of 10000h. This test method is also used for testing other oils, such as hydraulic oils and circulating oils having a specific gravity less than that of water and containing rust and oxidation inhibitors.
1.2 This standard adopts SI units.
1.3 This standard is involved in some materials, operations and equipments with hazard, but does not purport to address all of the safety concerns. Therefore, it is the responsibility of the user of this standard to establish appropriate safety and protective measures and determine the applicability of management system prior to use.
2 Normative References
The following standards contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest edition of these documents is applicable. For undated references, the latest edition of the normative document is applicable to this standard.
GB/T 12581-2006 The following standards are cited: