GB/T 30426-2013 Secondary cells and batteries containing alkaline or other non-acid electrolytes—Secondary lithium cells and batteries for portable applications
Secondary Cells and Batteries Containing Alkaline or Other Non-acid Electrolytes - Secondary Lithium Cells and Batteries for Portable Applications
1 Scope
This Standard specifies performance tests, designations, markings, dimensions and other requirements for secondary lithium single cells and batteries for portable applications.
The objective of this standard is to provide the purchasers and users of secondary lithium cells and batteries with a set of criteria with which they can judge the performance of secondary lithium cells and batteries offered by various manufacturers.
This standard defines a minimum required level of performance and a standardized methodology by which testing is performed and the results of this testing reported to the user. Hence, users will be able to establish the viability of commercially available cells and batteries via the declared specification and thus be able to select the cell or battery best suited for their intended application.
This standard covers secondary lithium cells and batteries with a range of chemistries. Each electrochemical couple has a characteristic voltage range over which it releases its electrical capacity, a characteristic nominal voltage and a characteristic end-of-discharge voltage during discharge. Users of secondary lithium cells and batteries are requested to consult the manufacturer for advice.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 2900.41-2008 Electrotechnical terminology - Primary and secondary cells and batteries [IEC 60050(482): 2003, IDT]
GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test [IEC 61000-4-2: 2001,IDT]
IEC 60051 Direct acting indicating analogue electrical measuring instruments and their accessories
IEC 60485 Digital electronic d.c voltmeters and d.c electronic analogue-to-digital converters
3 Terms and definitions
For the purpose of this Standard, the definitions contained in GB/T 2900.41-2008 and the following apply.
3.1 secondary lithium cell
Secondary single cell whose electrical energy is derived from the oxidation and the reduction of lithium. It is not ready for use in an application because it is not yet fitted with its final housing, terminal arrangement and electronic control device.
3.2 secondary lithium battery
Unit which incorporates one or more secondary lithium cells and which is ready for use. It incorporates adequate housing and a terminal arrangement and may have electronic control devices.
3.3 rated capacity
Quantity of electricity C5Ah (ampere-hours) declared by the manufacturer which a single cell or battery can deliver during a 5-h period, when charged, stored and discharged under the conditions specified in 7.2.1
3.4 nominal voltage
Suitable approximate value of voltage used to identify the voltage of a cell or battery.
NOTE 1: The nominal voltages of secondary lithium cells are given in Table 1.
NOTE 2: The nominal voltage of a battery of n series connected cells is equal to n times the nominal voltage of a single cell.
3.5 final voltage/end-of-discharge voltage
Specified closed circuit voltage at which a discharge of a cell or battery is terminated.
3.6 charge (capacity) retention
Capacity that a cell or battery can deliver after storage, at a specific temperature, for a specific time without subsequent recharging as a percentage of the rated capacity.
3.7 charge (capacity) recovery
Capacity that a cell or battery can deliver after the charge following the charge retention test.
4 Parameter measurement tolerances
The overall accuracy of controlled or measured values, relative to the specified or actual
values, shall be within these tolerances:
a) ±1% for voltage;
b) ±1% for current;
c) ±1% for capacity;
d) ±2°C for temperature;
e) ±0.1% for time;
f) ±0.1% for mass;
g) ±0.1% for dimensions.
These tolerances comprise the combined accuracy of the measuring instruments, the measurement techniques used, and all other sources of error in the test procedure.
For assistance in selecting instrumentation, see IEC 60051 for analogue instruments and IEC 60485 for digital instruments. The details of the instrumentation used shall be provided in any report of results.
5 Designation and marking
5.1 Cell and battery designation
Batteries shall be designated with following form: