1.1 Scope
This method specifies the method for determining chromium content in copper and copper alloys.
This method is applicable to the determination of chromium content in copper and copper alloys. The determination range is: 0.00005%~0.0010%.
1.2 Principle
Dissolve the test sample with nitric acid and then inject the test solution of certain volume into the electrothermal atomizer; measure the chromium absorbance at the wavelength of 357.9nm with the Zeeman effect atomic absorption spectrometer, and then calculate the mass fraction of chromium in the adoption of the working curve method.
1.3 Reagents
Unless otherwise stated, only identified analytical reagent and distilled water, or deionized water or water with equivalent purity shall be used for analysis. Vessels used for test shall be thoroughly rinsed with water after being soaked in nitric acid (1.3.3) for 12h.
GB/T 5121.16-2008 The following standards are cited:
GB/T 5121.16-2008 Cited by the following standards: