This standard specifies division of LPZ in wind profiler station, protection of wind profiler antenna, machine room and cable, selection of surge protection device, equipotential bonding and grounding and protection of removable wind profiler.
This standard is applicable to lightning protection design and construction of newly-built wind profiler station and removable wind profiler and used as a reference for design and construction for lightning protection reconstruction in wind profiler station.
2 Normative References
The following documents are essential for the application of this document. For dated reference, only the edition cited applies. For undated references, the latest edition (including any amendments) applies.
GB 50057-2010 Design Code for Protection of Structures against Lightning
GB 50601-2010 Code for Construction and Quality Acceptance for Lightning Protection Engineering of Structures
GB 50311-2007 Code for Engineering Design of Generic Cabling System
QX 2-2000 Technical Specifications for Lightning Protection at China New Generation Weather Radar Station
QX 4-2000 Technical Specifications for Lightning Protection at the Meteorological Offices (Stations)
QX/T 10.3-2007 Surge Protective Devices Part 3: Surge Protective Devices Connected to the Signaling Network of Elect
QX 30-2004 Technical Specifications for Lightning Protection at the Automatic Weather Stations
3 Terms and Definitions
For the purposes of this document, the following terms and definitions apply.
3.1
Wind profiler