This Part of GB 3836 specifies the particular requirements for construction, test and marking for electrical equipment that provides equipment protection level (EPL) Ga. This electrical equipment, within the operational parameters specified by the manufacturer, ensures a very high level of protection that includes rare faults related to the equipment or two faults occurring independently of each other.
Note 1: A malfunction may result from a failure of the component parts of the electrical equipment or from anticipated externally applied influences. Two independent malfunctions which may occur more frequently and which, separately, would not create an ignition hazard but which, in combination, could create a potential ignition hazard, should be regarded as occurring together to form a rare fault.
Note 2: This electrical equipment is intended for use in zone 0 hazardous areas, in which explosive gas atmospheres caused by mixtures of air and gases, vapours or mists under normal atmospheric conditions are present continuously, for long periods or frequently.
This standard also applies to equipment mounted across a boundary where different protection levels may be required.
Example: In the wall of a storage vessel containing zone 0 with an ambient defined as zone 1.
This Part also applies to equipment installed in an area requiring a lower protection level, but electrically connected to equipment with equipment protection level (EPL) Ga (associated apparatus).
This Part supplements the general requirements in GB 3836.1-2010 and the requirements of the standardized types of protection, in accordance with the GB 3836 series, to adapt the level of safety provided by those standards in order to provide EPL Ga.
Note 3: In designing equipment for operation in explosive gas atmospheres under conditions other than the atmospheric conditions given in GB 3836.1-2010, this standard may be used as a guide. However, additional testing is recommended related specifically to the intended conditions of use. This is particularly important when the types of protection ‘Flameproof enclosures’ (GB 3836.2-2010) and ‘Intrinsic safety’ (GB 3836.4-2010) are applied.
Note 4: The classification of hazardous areas in zones is defined in GB 3836.14-2000.
Note 5: There may be other non-electrical sources of ignition (for example ultrasonic, optical or ionizing radiation) that are not addressed by this standard; these should also be taken into consideration (see, GB/T 25285.1-2010).
Note 6: This concept provides equipment protection level (EPL) Ga. For further information, see Appendix A.
2 Normative References
The following normative documents contain provisions which, through reference in this text, constitute provisions of this Part of GB 3836. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this Part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.