This part of GB/T 18487specifies classification, general requirements, communication, electric shock protection, connection between electric vehicle and supply equipment, special requirements of vehicle coupler, plug and socket-outlet, supply equipment structure requirement, performance requirement, overload protection and short circuit protection, emergency stop, service conditions, repair, marking and description for electric vehicle conductive charging system.
This part is also applicable to EV supply equipment which acquires energy from onsite energy storage system (such as buffer battery).
Under the following special conditions, EV supply equipment shall provide additional functions:
a) Where the EV supply equipment is located in dangerous zone where there is flammable gas or steam, fuel or other combustible or explosive substance;
b) Where the EV supply equipment is designed as to be fixed at an altitude above 2 000 m.
This part is not applicable to safety requirements on maintenance of electric vehicle conductive charging system, or to the on-board charging equipment as specified in ISO 17409, or to power supply equipment of trolleybus, railway vehicle, and industrial vehicle and mainly for non-road vehicle.
2 Normative References
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB 1002 Single Phase Plugs and Socket-outlets for Household and Similar Purposes C Types, Basic Parameters and Dimensions
GB 1003-2008 Three Phases Plugs and Socket-outlets for Household and Similar Purposes C Types, Basic Parameters and Dimensions
GB 2099.1 Plugs and Socket-outlets for Household and Similar Purposes C Part 1: General Requirements
GB 7251.1-2013 Low-voltage Switchgear and Controlgear Assemblies C Part 1: General Rules (IEC 61439-1:2011, IDT)
GB 10963.1-2005 Electrical Accessories C Circuit-breakers for Overcurrent Protection for Household and Similar Installation C Part 1: Circuit-breakers for AC Operation (IEC 60898-1:2002, IDT)
GB 14048.2-2008 Low-voltage Switchgear and Controlgear C Part 2: Circuit-breakers
GB 14048.3-2008 Low-voltage Switchgear and Controlgear C Part 3: Switches, Disconnectors, Switch-disconnectors and Fuse-combination Units (IEC 60947-3:2005, IDT)
GB/T 14048.4-2010 Low-voltage Switchgear and Controlgear - Part 4-1: Contactors and Motor-starters C Low-voltage Electromechanical Contactors and Motor Starters (including Motor Protector)
GB 16895.3-2004 Electrical Installations of Buildings C Part 5-54: Selection and Erection of Electrical Equipment C Earthing Arrangements, Protective Conductors and Protective Bonding Conductors (IEC 60364-5-54:2002, IDT)
GB 16916.1-2014 Residual Current Operated Circuit-breakers without Integral Overcurrent Protection for Household and Similar Uses (RCCB) C Part 1: General Rules (IEC 61008-1:2002, MOD)
GB/T 16935.1-2008 Insulation Coordination for Equipment within Low-voltage Systems C Part 1: Principles, Requirements and Tests(IEC 60664-1:2007, IDT)
GB/T 17045-2008 Protection against Electric Shock C Common Aspects for Installation and Equipment (IEC 61140:2001, IDT)
GB/T 19596-2004 Terminology of Electric Vehicles
GB/T 20234.1-2015 Connection Set of Conductive Charging for Electric Vehicles - Part 1: General Requirements
GB/T 20234.2-2015 Connection Set of Conductive Charging for Electric Vehicles C Part 2: AC Charging Coupler
GB/T 20234.3-2015 Connection Set of Conductive Charging for Electric Vehicles C Part 3: DC Charging Coupler
GB/T 21711.1-2008 Electromechanical Elementary Relays C Part 1: General and Safety Requirements (IEC 61810-1:2003.IDT)
GB 22794-2008 Type B Residual Current Operated Circuit-breakers with and without Integral Overcurrent Protection for Household and Similar Uses (Type B RCCBs and Type B RCBOs) (IEC 62423:2007, IDT)
GB/T 27930-2015 Communication Protocols between Off-board Conductive Charger and Battery Management System for Electric Vehicle
GB/T 28569-2012 Electric Energy Metering for Electric Vehicle AC Charging Spot
GB/T 29317-2012 Terminology of Electric Vehicle Charging/Battery Swap Infrastructure
GB/T 29318-2012 Electric Energy Metering for Electric Vehicle Off-board Charger
GB 50057-2010 Design Code for Protection of Structures against Lightning
IEC 60269 (All Parts) Low-Voltage Fuses
IEC 60898 (All Parts) Electrical Accessories C Circuit-Breakers for Overcurrent Protection for Household and Similar Installations
IEC 60947-6-2:2007 Low-Voltage Switchgear and Controlgear C Part 6-2: Multiple Function Equipment C Control and Protective Switching Devices (or Equipment) (CPS)
IEC 61009-1:2013 Residual Current Operated Circuit-Breakers with Integral Overcurrent Protection for Household and Similar Uses (RCBOs) C Part 1: General Rules
IEC 6185l-23 Electric Vehicle Conductive Charging System C Part 23: DC Electric Vehicle Charging Station
IEC 62477-1:2011 Safety Requirements For Power Electronic Converter Systems And Equipment C Part 1: General
3 Terms and Definitions
For the purposes of this document, the terms and definitions given in GB/T 3505-2000 and GB/T 6062-2002 as well as those given below apply.
3.1 Charging system
3.1.1
Charging
Powering the power batteries of electric vehicle, or additionally on-board electric apparatus, at a calibrated voltage/current regulated from AC/DC network (power supply).
3.1.2
Charging modes
Method to power electric vehicle by connecting the electric vehicle to power network (power supply)